products
Fans
-
extremely long service life
-
compact design
-
motor and impeller assembled in one unit
-
the speed is 100% controllable (auto transformers; controller)
-
low start-up current
-
Rosenberg fans are equipped with motor protection through thermal contacts as a standard feature
-
The impellers are balanced on 2 levels according to DIN ISO 1940 (quality grade G2.5).

Axial Flow fans
Axial Wall Mounted
Axial Inline
– Explosion Proof
– Smoke 300 / 400 C for 2hours
Centrifugal Fans
- Direct Driven (Box, Duct, Rooftop, Tube, Plug, SISW, DIDW)
- Belt Driven (Forward and Backward Curved Impellers)
Centrifugal Fans (backward curved)
Free Running Impellers
Roof Fans
Tube Fans
Duct Fans
Fans made of Plastic
Explosion Proof Fans
The Directive 2014/34/EU governs the subject of “Explosion Protection” throughout the European Union. Regulations referring to placing products on the market to be utilized in areas with potentially explosive atmospheres are established in this specific directive. Rosenberg fans are designed in an explosion-proof version, manufactured and tested in accordance with the requirements of the following standards:
-
Explosive atmospheres – Basic concepts and methodology EN 1127-1
-
Non-electrical equipment for potentially explosive atmospheres, part 1 Basic method and requirements EN 13463-1
-
Non-electrical equipment for potentially explosive atmospheres, part 5 Protection by constructional safety “c” EN 13463-5
-
Design of fans working in potentially explosive atmospheres EN 14986

Air Handling Units

The requirements on a ventilation system are not always the same. In many applications, all that is required is a straightforward exchange of air, whereas in other applications the requirements can be very exacting with regard to temperature, humidity and purity of the air.
Rosenberg air handling units in the Airbox series have a modular design and can be individually configured. In this way, the appropriate solution can be assembled using a kind of modular principle for each application in a quick and straightforward procedure. Both, in the high-tech area and for classic building technology, air handling units from Rosenberg deliver clean air at the right tempered room climate. Weather-proof and explosion-proof designs are possible, as well as TÜV certified hygiene variants.
Overview of the unit series
The units consist of a framework structure with double-skinned panels that have acoustic and thermal insulating properties. The individual modules for the filter, fan, heater, cooler, heat recovery, acoustic insulation as well as the frame materials, are assembled flexibly according to the customers ‘requirements. The F40 series is produced in a frameless design. The panels are screwed together from the outside so that the devices are smooth internal surfaces and are hence hygienically safe.
The air handling units Airbox S60 and T60 are equipped with a framework construction made from aluminum or galvanized, rolled steel profiles and aluminium cast corner connectors or plastic corner connectors. The double-skinned panels of Airbox S60 and T60 air handling units are filled with non-combustible, sound and heat insulating rock wool insulation. In addition to galvanised steel panels and the framework construction, it is also possible to select coated steel, aluminium and stainless steel versions in our range. For modules with smaller dimensions, the base frame is manufactured in various heights (100, 300, 500 mm) using galvanised, folded steel sheet. Larger modules have a welded base frame (primed or galvanised).
AIRBOX-F40 | AIRBOX-S60 | AIRBOX-T60 | |
---|---|---|---|
Panel thickness: | 40 mm | 60 mm | 60 mm |
Frame: | frameless design | 1.5 mm galvanised steel | 1.5 mm aluminium and thermally decoupled |

Energy efficiency
The main factors which are important for the energy efficiency of an air handling unit are the air velocity in the profile unit face as well as the electric power consumption of the fan which is dependent on the air volume and pressure increase. In a combined air handling unit with heat recovery (HRU), the efficiency and pressure loss of the heat recovery must also be taken into account.
We work in accordance with the statutory requirements of the German Energy Saving Ordnance (EnEV), as well as the requirements of the German AHU Manufactures Association (RLT) when selecting the parameters for air velocity, the electrical power consumption of the fans and the efficiency of heat recovery. The criteria of the RLT energy efficiency label correspond to the standard DIN EN 13053 A1 (2011). This standard defines nine air velocity classes from V1 to V9, six heat recovery classes from H1 to H6 as well as six classes for the power consumption of fans from P1 to P6. The specific power consumption of a fan (SFP), installed in the air handling unit, is calculated as defined by the current DIN EN 13779.
AIR CURTAINS
Airtècnics is the vanguard of knowledge and technology in air curtains. With more than 30 years’ experience, we become a market leader, exporting to more than 55 countries worldwide. We design and produce a complete range of air curtains for all kind of applications and installations, including high energy efficiency EC motors, heat pump direct expansion coils and multiple jets. We offer tailor made, customized finishes and exclusive design solutions. Airtècnics provide basic and advanced regulation to fulfil all the market requirements. Our Clever Control with Modbus Protocol is ready to connect to BMS system, Windows PC and smartphones via Wi-Fi. Our air curtains are manufactured following high quality and reliably exclusive criteria, obtaining high performance and energy saving combined with an innovative design.
We are providing three categories of air curtains:
- Commercial Air Curtains
- Decorative Air Curtains
- Industrial Air Curtains

Commercial Air Curtains
Decorative Air Curtains
Industrial Air Curtains
ZEN Air Curtain Finishes
